MRI DEEP RESOLVE BOOST –SPINE – PART1
Deep Resolve Boost has been available for a while now, and based on my experience, I want to create a series of videos sharing tips and tricks. Today, we’re focusing on the lumbar spine; T2w transverse plane. There are some key parameters that can make the images stand out. Join me in exploring and learning more about this topic, and don't miss out on this opportunity to enhance your knowledge.
Remember to check out and support my PATREON here: www.patreon.com/bacmri
Thanks for watching, following and support.
#S_MAGNETIC_VLOG #MRI #SIEMENSHEALTHINEERS #DRB #MEDICAL_IMAGING #MRI_TECHNOLOGIST #MEDICINE #MRI_RADIOGRAPHER #MRIRADIOGRAPHER #RADIOLOGY #PATREON
References:
Rem Sun - In Her Arms (Vlo...
Просмотров: 2 354

Видео

MRI BACK TO BASIC - SLICE RESOLUTION
Просмотров 3,4 тыс.Месяц назад
Let’s dive into the topic of slice resolution. This important parameter is key to understanding 3D acquisitions. Join me in exploring and learning more about slice resolution in MRI, and don't miss out on this opportunity to enhance your knowledge. Remember to check out and support my PATREON here: www.patreon.com/bacmri Thanks for watching, following and support. #S_MAGNETIC_VLOG #MRI #SIEMENS...
MRI SWI OF THE SPINE - HOW I DO IT
Просмотров 2,8 тыс.Месяц назад
In this video I want to share with you how I did SWI of the spine. While SWI is typically associated with brain imaging, its application to the spine is less conventional yet entirely feasible. Don't miss out on this opportunity to explore and learn with me. Remember to check out and support my PATREON here: www.patreon.com/bacmri Thanks for watching, following and support. #S_MAGNETIC_VLOG #MR...
MRI 3D PHASE CONTRAST (3D-PC) - POST-PROCESSING
Просмотров 2,7 тыс.2 месяца назад
Today's the day I unveil my routine for 3D Phase Contrast. Join me in this video as I demonstrate in details of the post-processing with XA software on a Siemens scanner. Don't let this chance slip away - tune in and discover with me. Remember to check out and support my PATREON here: www.patreon.com/bacmri Thanks for watching, following and support. #S_MAGNETIC_VLOG #MRI #SIEMENSHEALTHINEERS #...
MRI SCANNER ROOM - IMPORTANT KEY FACTOR
Просмотров 2,1 тыс.2 месяца назад
Join me and my daughter in this short video as we demonstrate two crucial scenarios for your scanner room. One of these scenarios is guaranteed to alleviate anxiety and stress for both children and adults alike. Don't miss out on this opportunity to learn more - tune in and join us! Remember to check out and support my PATREON here: www.patreon.com/bacmri Thanks for watching, following and supp...
MRI - TOF - POST-PROCESSING
Просмотров 4,1 тыс.3 месяца назад
MRI - TOF - POST-PROCESSING Today, I'm thrilled to demonstrate how I run a 3D TOF. During this video, I will also showcase the post-processing part using XA software on a Siemens scanner. Don't miss out on this opportunity - tune in and join me to learn more. Remember to check out and support my PATREON here: www.patreon.com/bacmri Thanks for watching, following and support. #S_MAGNETIC_VLOG #M...
MRI - PREVENT NEXT SEQUENCE AUTO OPENING
Просмотров 3 тыс.3 месяца назад
MRI - PREVENT NEXT SEQUENCE AUTO OPENING Today, I’m thrilled to reveal a solution to prevent the automatic opening of the following sequence on a Siemens MRI system. Whether you're using XA software or an older version, this method will apply. Don't miss out on this opportunity - tune in and join me to learn more. Remember to check out and support my PATREON here: www.patreon.com/bacmri Thanks ...
MRI - CE-MRA NECK & POST-PROCESSING
Просмотров 4,3 тыс.4 месяца назад
Today, I’m thrilled to demonstrate the straightforward process of performing Contrast Enhanced MRA of the neck, and I’ll be sharing some invaluable tips and tricks for seamless post-processing using View&Go (XA software). Don’t miss out - tune in and join me. Remember to check out and support my PATREON here: www.patreon.com/bacmri Thanks for watching, following and support. #S_MAGNETIC_VLOG #M...
MRI - FLIP ANGLE (EXCITATION PULSE)
Просмотров 3,8 тыс.4 месяца назад
In this video I will show you how to enable the excitation pulse (if having it available). The flip angle pulse we usually can change is the refocussing pulse, not excitation. I was surprised the excitation pulse can be controlled at all. Let’s do some test to see how it works. Tune in and join me. Remember to check out and support my PATREON here: www.patreon.com/bacmri Thanks for watching, fo...
MRI - DWI - INNER EAR IMAGING
Просмотров 4,3 тыс.5 месяцев назад
This video is all about DWI in the inner ear. I’m going to do this on a 3T scanner which is far more challenging compared to a lower field strength. Nr.1 enemy for DWI is distortion, and with different DWI techniques we will try to minimize this artifact. Tune in and join me. Remember to check out and support my PATREON here: www.patreon.com/bacmri Thanks for watching, following and support. #S...
MRI - PEARL TECHNOLOGY
Просмотров 2,5 тыс.5 месяцев назад
Certainly, fixation is a crucial aspect of obtaining high-quality images during MRI scans. Proper patient positioning and immobilization are essential for minimizing motion artifacts and ensuring accurate diagnostic imaging. It will also contribute to a more comfortable and less anxious experience for the patient during scanning. Tune in and join me on this one and I will show you what kind of ...
MRI - BODY HEALS ITSELF
Просмотров 1,8 тыс.6 месяцев назад
Last video of this year, and I just want to say how grateful I’m with all the support. This channel wouldn’t have been the same without you guys. Today’s case I want to share a case where we can see how the body heals itself. Tune in and join me Happy holiday season everyone Remember to check out and support my PATREON here: www.patreon.com/bacmri Thanks for watching, following and support. #S_...
MRI - KYPHOLIFT
Просмотров 4,3 тыс.7 месяцев назад
Kypholift is an equipment for kyphosis patient which makes the workflow more safe, efficient and accurate. With kypholift you’re now able to position these kind of patients alone without the need of 2-3 colleagues for lifting and improvising the patient positioning. Not only that, kypholift can also be used on other modality such as CT, Xray etc. Remember to check out and support my PATREON her...
MRI - T1w 3D SPACE - BRACHIAL PLEXUS
Просмотров 4 тыс.8 месяцев назад
I’m going to talk specific about one sequence on this brachial plexus protocol, T1w 3D SPACE. We bumped into a few challenges when we tried to optimise this for plexus. A small adjustment made very much improvements. Honestly, it surprised me. Remember to check out and support my PATREON here: www.patreon.com/bacmri Thanks for watching, following and support. #S_MAGNETIC_VLOG #MRI #SIEMENSHEALT...
MRI - GRASP VIBE - TROUBLESHOOTING
Просмотров 5 тыс.8 месяцев назад
In this video I will briefly explain how GRASP VIBE works, and how to overcome especially one challenging factor which really bothers me. Remember to check out and support my PATREON here: www.patreon.com/bacmri Thanks for watching, following and support. #S_MAGNETIC_VLOG #MRI #SIEMENSHEALTHINEERS #KNEE #GRASP_VIBE #DWI #MEDICAL_IMAGING #MRI_TECHNOLOGIST #MEDICINE #MRI_RADIOGRAPHER #MRIRADIOGRA...
MRI - UNILATERAL HIP
Просмотров 3,9 тыс.8 месяцев назад
MRI - UNILATERAL HIP
MRI - KNEE - SIGNAL INTENSITY
Просмотров 3,5 тыс.9 месяцев назад
MRI - KNEE - SIGNAL INTENSITY
MRI - NECK IMAGING - A USEFUL TIP
Просмотров 6 тыс.9 месяцев назад
MRI - NECK IMAGING - A USEFUL TIP
MRI - SLICE COVERAGE - A USEFUL TIP
Просмотров 6 тыс.10 месяцев назад
MRI - SLICE COVERAGE - A USEFUL TIP
MRI - KIDNEY IMAGING - DEEP LEARNING
Просмотров 8 тыс.11 месяцев назад
MRI - KIDNEY IMAGING - DEEP LEARNING
MRI - BRACHIAL PLEXUS - DWI
Просмотров 6 тыс.Год назад
MRI - BRACHIAL PLEXUS - DWI
MRI - SCAPULA w/DEEP RESOLVE
Просмотров 6 тыс.Год назад
MRI - SCAPULA w/DEEP RESOLVE
MRI - FASTVIEW LOCALIZER
Просмотров 3,3 тыс.Год назад
MRI - FASTVIEW LOCALIZER
MRI - AVERAGES - BACK TO BASIC
Просмотров 8 тыс.Год назад
MRI - AVERAGES - BACK TO BASIC
MRI - CONCATENATIONS - BACK TO BASIC
Просмотров 12 тыс.Год назад
MRI - CONCATENATIONS - BACK TO BASIC
MRI - MATRIX BACK TO BASIC
Просмотров 11 тыс.Год назад
MRI - MATRIX BACK TO BASIC
MRI INFORMATION VIDEO - HOW WE DID IT
Просмотров 3,8 тыс.Год назад
MRI INFORMATION VIDEO - HOW WE DID IT
MRI SHOULDER “DYNAMIC” - HOW I DID IT
Просмотров 6 тыс.Год назад
MRI SHOULDER “DYNAMIC” - HOW I DID IT
MRI DEEP RESOLVE BOOST (DRB) - TIPS & TRICKS
Просмотров 7 тыс.Год назад
MRI DEEP RESOLVE BOOST (DRB) - TIPS & TRICKS
MRI Susceptibility Weighted Imaging (SWI) @ 3T
Просмотров 11 тыс.Год назад
MRI Susceptibility Weighted Imaging (SWI) @ 3T

Комментарии

  • @mohamedelfaki9616
    @mohamedelfaki9616 День назад

    In sag use phase H to F And what is PAT

  • @MrSaheb-n9e
    @MrSaheb-n9e 3 дня назад

    How to add Lipid

  • @divyank.t.5710
    @divyank.t.5710 4 дня назад

    Hi.. What could happen if we reduce the average of spectroscopy from 3 to 1 or 2.. Will that do anything to the results(peaks in the graph)? Thanks..

    • @Nguyen_MRI
      @Nguyen_MRI 4 дня назад

      @@divyank.t.5710 you can of course save time but might also struggle from low snr

    • @divyank.t.5710
      @divyank.t.5710 4 дня назад

      @@Nguyen_MRI thanks for the response.. What could the low Snr do to spectro?

    • @Nguyen_MRI
      @Nguyen_MRI 4 дня назад

      @@divyank.t.5710 i haven't been there to try that. But I'm sure the peaks comes out badly. Doing a single voxel can be helpful in time savings.

  • @umminasrah3253
    @umminasrah3253 4 дня назад

    if im using syngo fastview , where should i discover the number of slices ?

    • @Nguyen_MRI
      @Nguyen_MRI 4 дня назад

      @@umminasrah3253 number of slices you can't change i believe. So it covers the whole anatomy. Area of scanning in all planes.

  • @cher545
    @cher545 5 дней назад

    Starting mri tech school in illinois at end of july. Was referred to you by mri guy. Glad i came to your channel.

    • @Nguyen_MRI
      @Nguyen_MRI 5 дней назад

      Thank you. Wish you the best with school and work ☺️

  • @aneetaedwards3775
    @aneetaedwards3775 9 дней назад

    thanks bac really appreciate

  • @aneetaedwards3775
    @aneetaedwards3775 9 дней назад

    bac i am unable to see your reply

    • @Nguyen_MRI
      @Nguyen_MRI 9 дней назад

      hi its under exam card - CONTRAST - COMMON - Wrap-Up Magn - RESTORE

  • @aneetaedwards3775
    @aneetaedwards3775 9 дней назад

    hi bac hope your doing good, i am working on sola how can i set up restore mag pulse

    • @Nguyen_MRI
      @Nguyen_MRI 9 дней назад

      hi its under exam card - CONTRAST - COMMON - Wrap-Up Magn - RESTORE

  • @OmarM8055
    @OmarM8055 11 дней назад

    Do you know were I can find same study but for GE 1.5 T enhance imaging ??

    • @Nguyen_MRI
      @Nguyen_MRI 11 дней назад

      I'm sorry I'm not familiar with GE.

  • @monirmotaharian
    @monirmotaharian 12 дней назад

    very good

  • @calbang
    @calbang 13 дней назад

    If youre getting that smearing appearance I would recommend reducing your acceleration. You really only get that if youre source images are too noisy.

    • @Nguyen_MRI
      @Nguyen_MRI 12 дней назад

      Thanks for the input ☺️

  • @local93
    @local93 13 дней назад

    Btw, is it applicable for joints with flex coils? Or without dedicated coils it is not great idea? Also with 3T mri I honestly don’t see any reasons to improve quality 😂

    • @Nguyen_MRI
      @Nguyen_MRI 13 дней назад

      Good questions. Applicable with all coils. And for 3T for better images and scan time purposes.

    • @brainthesizeofplanet
      @brainthesizeofplanet 10 дней назад

      uh.... - The Siemens solution is currently inferior to the GE AirRecon DL and that by quite a a bit. With AirRecon DL u can acquire a much higher resolution and thinner slices than before in less time - i.e a knee Exam in 2.5mm and 0.5/0.4 voxel size in less than 7 minutes - the difference is remarkable

    • @calbang
      @calbang 8 дней назад

      ​@@brainthesizeofplanet I've been able to do 0.2mm voxel size in that same time on a Siemens. I think you might need to revisit your sequences. Also, I heard the GE Recon looks really smooth and plastic. Is this still the case?

    • @brainthesizeofplanet
      @brainthesizeofplanet 8 дней назад

      @@calbang If u have the time u can do it - but better check that u are actually scanning in 0.2, most Siemens scanner show the calculated voxel size and not what u are scanning in. .what scanner are u using it on? The denoising if the GE solution is better and yes in high it looks very smooth/plastic - that's the result if the denoising . I doubt many ppl have a GE and Siemens with DL to compare, what I can tell for now is that the GE solution is more flexible, more advanced (3D sequences, blade and tse) and has better denoising - GE is currently running circles around Siemens with DL and they have a advantage of about 3 years in term of development i.e k-space artifact removal (gibbs, pulsation), complete k-space DL (Siemes is partly in 2d postprocessing), faster denoising calculations, a lot more sequences

    • @calbang
      @calbang 7 дней назад

      ​@@brainthesizeofplanet Acquiring voxel <0.4mm and reconstructed to 0.2mm. Something GE hasn't figured out how to do I believe, they're purely denoising and no super resolution? Ive also got access to both and found Siemens much higher image quality and sharper images. We always take patients off the GE with DL because the images are so smooth.

  • @iansze2652
    @iansze2652 13 дней назад

    Bac great videos as always, I just have a concept question regarding DRB: Why do DRB sequences tend to wrap so much? I notice that at my previous site that used DRB the Phase Oversample is always set at 200% vs 100% or even 150%, or you would get wrapping artifacts. Thanks!

    • @Nguyen_MRI
      @Nguyen_MRI 13 дней назад

      Correct. Using tse separste mode as far my experience you need to go beyond with phase oversampling as you say. Especially having small fov. It's sense parallel imaging based. Using integrated you can optimise as from what you are used to without Drb. But then sometimes images can turned out bad. Need to find the balance between those two options.

    • @brainthesizeofplanet
      @brainthesizeofplanet 10 дней назад

      No it is mainly not about wrapping artifacts! - it is because of SNR and how DRB works or what u want. You can only get a faster exams by upping P value or reducing NEX. Most ppl also want a higher in plane resolution or thinner slices. So sometimes you reduce NEX to 1 from 2 and depending on the resolution your SNR is tool low even von DRB high. The other scenario is that u already have only 1 NEX ad can't go an lower here but want better and faster images, so u set grappa to 3 or 4 (4 introduces a sig noise and loss of detail) and u raise the resolution - in those cases u mostly get a 10-20% increase in in-plane Resolution. In both scenarios u can end up with not enough SNR in DRB high and u need oversampling to get 5-10% SNR "back" - that is why oversampling with DRB is mostly always higher set than it was with older protocols. This is also one of the main difference GE vs Siemens as GE offers "half nex" for TSE and 0.1 steps for Blade sequences. With GE u have much more flexibility in terms of speed and SNR with DL / AirRecon DL than u get with the Siemens system - we have a Siemens with DRB and a GE with "full" AirDL. Currently AirRecon DL is hugely superior to DRB - cleaner images, less artifacts (pulsation and gibbs artifact gets removed in k-space). Also the recon time faster, Siemens needs 25-30s per series to compute and display and GE only 5-10.

    • @Nguyen_MRI
      @Nguyen_MRI 10 дней назад

      @@brainthesizeofplanet thanks for the input. 👍. They all got pros and cons in general. I'm not lucky as you to have those two vendors for comparison 🥲

    • @calbang
      @calbang 8 дней назад

      ​@@brainthesizeofplanetmy images on Siemens are reconstructing mid sequence with Deep Resolve.

  • @chrisunguez
    @chrisunguez 13 дней назад

    I seem to get far more flow artifact from the abdominal aorta in my DRB sagittal images, particularly the STIRS. Sat bands and additional averages do not seem to fix it. Any suggestions?

    • @iansze2652
      @iansze2652 13 дней назад

      Add a NEX and compensate for time/signal increase

    • @chrisunguez
      @chrisunguez 13 дней назад

      @@iansze2652 As mentioned initially, adding an average does not fix it. I haven’t run more than 2 NEX, but adding a third basically negates the time saving benefits of DRB.

    • @iansze2652
      @iansze2652 13 дней назад

      @@chrisunguez Hmmm, I assume also you've tried sat bands superior to the stack as well and this also doesn't work...I think all that's left is swapping your phase. I think sometimes adding even one more average in addition to the other fixes mentioned above may actually minimize the artifact/move it off the AOI. It would also depend on whether you are scanning on a 1.5T or a 3T, as a 3T would natrually pick up more motion/breathing/flow artifacts.

    • @chrisunguez
      @chrisunguez 13 дней назад

      @@iansze2652 Superior sat bands don’t seem to help, either. I hadn’t considered swapping phase, since I’d assumed the breathing artifact A>P or P>A would be just as bad. But thanks, I might try F>H rather than H>F. Not sure if it’ll help, but worth a shot. Also, we only have DRB on our 1.5T at the moment. I’m curious to see how these various DRB artifacts look at a higher field strength.

    • @renzoalejos5965
      @renzoalejos5965 13 дней назад

      @@chrisunguezhola, puedes probar cambiando la dirección de fase en F/H, disminuyendo el flip angle que también ayuda a diminuir los artefactos de movimientos y flujo,adicional a ello puedes colocar compensación de flujo en frecuencia y lo más importante… un posicionamiento correcto del paciente para evitar el artefacto de anefacto el cual se produce por recepción de señal fuera del FOV en zonas donde hay bobinas activadas

  • @Fletch001
    @Fletch001 13 дней назад

    Outstanding information..!

  • @local93
    @local93 13 дней назад

    What is about acceleration factroe PE and Reference Lines PE? Is it worth it to change them or it is better leave them as it is

    • @Nguyen_MRI
      @Nguyen_MRI 13 дней назад

      You can try and play with those settings. But most of the time it's between choosing integrated vs tse separate

    • @scottgloverjohnson
      @scottgloverjohnson 12 дней назад

      If your ipat is set really high it may be worth it to add some additional reference lines so that the ref scan, whether separate or integrated, will be a bit more robust. If you don't have enough phase encoded data in some form, you can end up with like only 50 lines in the ky direction if you're not careful. Shouldn't affect time too much to increase it. Like Bac says double check what happens when you change it. Very high ipat and very few ref lines starve the reconstruction of real data, but deep resolve will still try to fill the gaps by making stuff up.

  • @aneetaedwards3775
    @aneetaedwards3775 14 дней назад

    hi there using phase Fourier like 7/6 i can able to reduce the scan time, but snr is also dropping, which is the best way to use this phase Fourier

    • @Nguyen_MRI
      @Nguyen_MRI 14 дней назад

      Depends on sequence and parameters used.

  • @djfhdjfjfh659
    @djfhdjfjfh659 15 дней назад

    At athor mri machine like get and Philips what's the name of gtaspa vibe thankd

    • @Nguyen_MRI
      @Nguyen_MRI 15 дней назад

      I don't think Philips have similar.

  • @onderaltug
    @onderaltug 18 дней назад

    incredible.

  • @iggyantioch
    @iggyantioch 18 дней назад

    Can you use ppg if cardiac isn't working

    • @Nguyen_MRI
      @Nguyen_MRI 18 дней назад

      I never tried. But should work

  • @jim8439
    @jim8439 19 дней назад

    I have found that increasing PE steps to 100% also reduces ghosting artefact quite well.

  • @aneetaedwards3775
    @aneetaedwards3775 20 дней назад

    thank for your quick response, we position head first but when coming to T1 spine echo even the flip angle is low but still its give the SAR issue, so its accept with more TR value. after increasing the TR its allows us to proceed the scan.

    • @Nguyen_MRI
      @Nguyen_MRI 20 дней назад

      Adjust also Rf pulse.

  • @aneetaedwards3775
    @aneetaedwards3775 20 дней назад

    hi i always follow your videos they are very helpful. i have a doubt , i working with siemens sola when ever if we position feet first for legs, are pelvis examinations we use to get a SAR issues, my line manager said you can position head, but still i have a SAR issue, can please guide me

    • @Nguyen_MRI
      @Nguyen_MRI 20 дней назад

      Head first reduce this issue. But also check this video. ruclips.net/video/cNeufIi9pEA/видео.htmlsi=uNE6DiLiKbLM8qc2

  • @sagarkapile3800
    @sagarkapile3800 22 дня назад

    Which sequence use

    • @Nguyen_MRI
      @Nguyen_MRI 22 дня назад

      3d truefisp ECG and resp triggered.

    • @Nguyen_MRI
      @Nguyen_MRI 22 дня назад

      ruclips.net/video/KgjtRH8VwD4/видео.htmlsi=Bz4TVYesFQ_KgEzn

  • @thanzeeltabassum1641
    @thanzeeltabassum1641 23 дня назад

    Is there any detail vedio?

  • @thanzeeltabassum1641
    @thanzeeltabassum1641 23 дня назад

    How you did thiz ?

    • @Nguyen_MRI
      @Nguyen_MRI 23 дня назад

      Modified a high t2w sequences such as an mrcp.

  • @IsmaelKhalefa
    @IsmaelKhalefa 24 дня назад

    Great work❤

  • @ClessieCummins254
    @ClessieCummins254 25 дней назад

    Good job man! Viets are always going above and beyond!

  • @aakib_parray1470
    @aakib_parray1470 29 дней назад

    Link please

    • @Nguyen_MRI
      @Nguyen_MRI 29 дней назад

      www.amazon.com/Handbook-MRI-Technique-Catherine-Westbrook/dp/1119759331/ref=mp_s_a_1_2?crid=7VDC5HJ7QMAU&dchild=1&keywords=handbook+of+mri+technique&qid=1632856339&sprefix=handbook+of+mri&sr=8-2

  • @nareshreddy3608
    @nareshreddy3608 Месяц назад

    How to calculate the hippocampus in relaxometry

    • @Nguyen_MRI
      @Nguyen_MRI Месяц назад

      Good question. Never done that. I guess some third part software are available for that.

  • @TZLH716
    @TZLH716 Месяц назад

    Can you please help me I have essential tremors I can double click to open things but I can’t connect the lines when I MIP angios is there a shortcut without double clicking we use Siemens 3T Ty in advance

    • @Nguyen_MRI
      @Nguyen_MRI Месяц назад

      mip not always working .special not reference lines. try raw data of angios. it should work.

  • @gracefulonthetrail2244
    @gracefulonthetrail2244 Месяц назад

    Can you please tell me the software version you are using here? I'm in clinicals and the hospital I'm at uses this with their 1.5T Aera and I'm not familiar with the icons and their meaning. The tech there doesn't know what version of Seimens software it is. I was hoping to find info online with no luck. Thank you for doing these awesome videos! It helps me a lot!

    • @Nguyen_MRI
      @Nguyen_MRI Месяц назад

      It's Siemens E11e software. You probably have similar E11 also.

  • @emrearslan8274
    @emrearslan8274 Месяц назад

    I am working at siemens vida and i don't have a coil for shoulders and we are using flexi coil and we have action artefact so can you teach me a solution ?

    • @Nguyen_MRI
      @Nguyen_MRI Месяц назад

      What flexi coil is this? Ultraflex 18ch?

    • @emrearslan8274
      @emrearslan8274 Месяц назад

      @@Nguyen_MRI yes sir

    • @Nguyen_MRI
      @Nguyen_MRI Месяц назад

      @@emrearslan8274 i need to see some images. And i don't know how you position your patients and coil. Arms etc.

    • @Nguyen_MRI
      @Nguyen_MRI Месяц назад

      I would do it more or less like this: ruclips.net/video/4nr2ZdAdT_o/видео.htmlsi=p8_QunEs9Y7bPLb5

    • @emrearslan8274
      @emrearslan8274 Месяц назад

      Thank you sir i am watching right now and i wil try something if i don't fix this problem i will be write you again. Thanks your support

  • @sahin314
    @sahin314 Месяц назад

    Hello mr. How can I learn all parametres about siemens Mrı for example about "pat mod " grappa,msense or caipsirina, or etc parametres T2 decay, about bandwith and others. How can I learn.( sorry about my English🙏)

    • @Nguyen_MRI
      @Nguyen_MRI Месяц назад

      Many great learning platforms out there. Just have to Google specific topics because mri is a very wide topic. Start basic.

    • @hasanchaudhary8950
      @hasanchaudhary8950 22 дня назад

      MRI master is best

  • @interwebzful
    @interwebzful Месяц назад

    love these back to basics. this one was especially awesome

  • @mihaimoldo
    @mihaimoldo Месяц назад

    Great video Bac! Btw you can think it as a second phase encoding, that's why you can get wrap-around artifacts in the slice direction.

    • @Nguyen_MRI
      @Nguyen_MRI Месяц назад

      Thanks for input. Indeed ☺️👍

  • @selimakko9811
    @selimakko9811 Месяц назад

    👍🏻

  • @yusraaoraen
    @yusraaoraen Месяц назад

    Does it work the same for the 3D whole heart?

    • @Nguyen_MRI
      @Nguyen_MRI Месяц назад

      Indeed it does

    • @yusraaoraen
      @yusraaoraen Месяц назад

      What slice thickness do you suggest if they want to see coronaries?

    • @Nguyen_MRI
      @Nguyen_MRI Месяц назад

      @@yusraaoraen thin as possible. 0.9-1mm max.

    • @yusraaoraen
      @yusraaoraen 26 дней назад

      I did before with 0.65-0.75mm in cardiac congenital scans. In most, the image resolution was not that great to see coronaries. Thank you for the suggestion!

  • @robertanderson3700
    @robertanderson3700 Месяц назад

    👏👏👏👏 que massa

  • @hishamvadakkekkandi
    @hishamvadakkekkandi Месяц назад

    First

  • @user-hx5zv7xe9h
    @user-hx5zv7xe9h Месяц назад

    you are the best !

  • @user-hx5zv7xe9h
    @user-hx5zv7xe9h Месяц назад

    yes of course i like it thank you again !

  • @angviethung791
    @angviethung791 Месяц назад

    I see that you can choose one of two dimensions: frequency and slice. Which direction should I choose and why?

    • @Nguyen_MRI
      @Nguyen_MRI Месяц назад

      READ - sagittal and coronal. SLICE - transversal.

    • @angviethung791
      @angviethung791 Месяц назад

      @@Nguyen_MRI Can I ask why you chose that?

    • @Nguyen_MRI
      @Nguyen_MRI Месяц назад

      @@angviethung791mri physics are like that. Or it won't work properly.

    • @Nguyen_MRI
      @Nguyen_MRI Месяц назад

      mriquestions.com/flow-compensation.html

  • @user-hx5zv7xe9h
    @user-hx5zv7xe9h Месяц назад

    thanks for spreading knowledge as simply as you can ! i think it's great !

  • @user-hx5zv7xe9h
    @user-hx5zv7xe9h Месяц назад

    thanks really from the bottom of my heart

  • @billyidolman4666
    @billyidolman4666 Месяц назад

    Does anyone else find this confusing as heck??

  • @nuralamin6780
    @nuralamin6780 Месяц назад

    Well done ! But can you please tell me , what is the need of making the TMJ dynamic by getting patient more exposed to radiation ?

    • @Nguyen_MRI
      @Nguyen_MRI Месяц назад

      Good question. You don't get exposed with radiation using mri. CT you do get exposed. And for dynamic more info here: www.sciencedirect.com/science/article/pii/S2352047721000708

  • @furreh
    @furreh Месяц назад

    Love your videos, hemosiderin deposits are what we usually use SWI in MSk examinations. We havn't dabbled into SWI for the spine, but I could see it becoming useful in post-bleeding cases. Do you have any advice for SWI in the upper extremities where we are lacking in specialized coils?

    • @Nguyen_MRI
      @Nguyen_MRI Месяц назад

      Upper you want to try that? What scanner and coil you have.?

    • @furreh
      @furreh Месяц назад

      @@Nguyen_MRI 1.5T SOLA / 3T VIDA. We have shoulder coil, but wrist and elbow are flex. (Currently we're doing knees regularly and feet rarely).

    • @Nguyen_MRI
      @Nguyen_MRI Месяц назад

      @@furreh Try ultraflex. Those are very good one.

  • @Ahaha4
    @Ahaha4 Месяц назад

    Hi Bac, thank you for your video🤝👍💪 Tell me pls, Vida 3t is it Sola but 1,5t?))

    • @Nguyen_MRI
      @Nguyen_MRI Месяц назад

      Same plattform yes.biomatrix. 3T vs 1.5T.

    • @Ahaha4
      @Ahaha4 Месяц назад

      @@Nguyen_MRI Thanks 🙏🏻

    • @Nguyen_MRI
      @Nguyen_MRI Месяц назад

      @@Ahaha4 you're welcome ☺️

  • @francjanum3935
    @francjanum3935 Месяц назад

    Great Buddy good insight!!